Kostenloser Versand ab 35€ (DE)
4.9 / 5 | 2847 Bewertungen
30 Tage Geld-zurück-Garantie
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel
  • Load the image into the gallery viewer, Forte - Red Light Panel

Forte - Red Light Panel

Red light lamp
Normal price
2.190,00 €
Special price
2.190,00 €
Normal price
Sold out
unit price
per 
incl. VAT plus shipping costs
  • 4 wavelengths: 630, 660, 810 & 850 nm
  • 6 presets + 2 individually savable programs
  • Flexible for use as a single or dual setup
Auf Lager - In 2 bis 4 Werktagen bei dir Zuhause

Kostenloser Versand ab 35€
mit DHL innerhalb Deutschlands

Risikofrei bestellen
30 Tage Geld-zurück-Garantie

Lichtblock® Forte Red Light Panel

Forte is our large red light panel for large-area application of red and near-infrared light. With four wavelengths, intuitive operation, and versatile setting options, Forte can be easily adapted to different applications and routines.

Easy operation directly on the panel

Forte is operated via the integrated touch display on the side. Here you can select presets, create your own settings, or connect and control two panels together.

6 presets for different applications

Forte offers six fixed presets for different applications. Simply choose the desired preset and start the application with the settings already saved.

Preset Energy
Energy

For energizing applications.

Red 100% / NIR 100%
10 min. / 40 Hz

Preset Pre Workout
Pre Workout

For short applications before physical activity.

Red 100% / NIR 100%
5 min. / Pulse off

Preset Recovery
Recovery

For applications after physical exertion.

Red 100% / NIR 100%
10 min. / Pulse off

Preset Relax & Meditation
Relax & Meditation

For relaxing applications and rest periods.

Red 50% / NIR 50%
20 min. / 10 Hz

Preset Sleep
Sleep

For evening applications.

Red 0% / NIR 100%
10 min. / Pulse off

Preset Skin & Beauty
Skin & Beauty

For targeted applications on the face or skin.

Red 100% / NIR 100%
3 min. / Pulse off

Your own programs

In addition to the six fixed programs, Forte offers two user presets that you can freely configure and save. This lets you call up your preferred configuration again at any time.

For your own programs and in Custom mode, you can individually select the intensity of red light and near-infrared, set a duration between 1 and 60 minutes or Infinity mode, and activate a pulse frequency between 1 and 40 Hz if needed. The pulse function is also part of the fixed Relax & Meditation program at 10 Hz and Energy at 40 Hz.

Red light and near-infrared with four wavelengths

Forte combines visible red light at 630 and 660 nm with near-infrared light at 810 and 850 nm. Both spectral ranges have been intensively studied in photobiomodulation research for many years. Red light and near-infrared can be adjusted independently in intensity or used together.

The panel uses 450 dual-chip LEDs with a total of 900 LED chips. Each of the four wavelengths is assigned 225 chips.

Spectral measurement of the Forte red light panel with 630, 660, 810 and 850 nm

Original spectral measurement graphic in combined red light and near-infrared operation.

Red light and near-infrared light in research

The application of red and near-infrared light is often grouped under the term photobiomodulation and has been studied scientifically for many years. Research explores, among other things, how light of certain wavelengths is absorbed by cells and how it can influence biological processes there.

Mitochondria play an important role here, as they are responsible for energy production in our cells. Research describes, among other things, changes in cellular energy metabolism and various signaling processes. Today, photobiomodulation is being studied in different areas, for example in connection with physical activity and regeneration as well as skin and general well-being.

How light acts biologically does not depend on wavelength alone. Intensity, duration, distance, and the total amount of light absorbed also play a role.

Single or dual setup

Forte can be used on its own or together with a second panel. In a dual setup, both panels are connected with a data cable and controlled together via the touch display of the master panel.

Two Forte panels create a continuous area of 45 × 182 cm. The vertical stand, horizontal stand, and wall mount can each be used with one or two panels.

Four mounting options

Lichtblock Forte red light panel with stand
Stand

The compact solution for a single Forte panel. The stand is on casters and allows flexible positioning in the room.

Lichtblock Forte red light panel with vertical stand
Vertical Stand

For upright use with one or two Forte panels. The height of the stand can be adjusted individually.

Lichtblock Forte red light panel with horizontal stand
Horizontal Stand

For horizontal use with one or two Forte panels. The height of the stand can be adjusted individually.

Lichtblock Forte red light panel with wall mount
Wall Mount

For fixed, space-saving installation of one or two Forte panels on the wall.

Note: Stands and wall mount are available separately.

All features at a glance

  • 4 wavelengths: 630, 660, 810 and 850 nm
  • 450 dual-chip LEDs with a total of 900 LED chips
  • Red light and near-infrared light with independently adjustable intensity
  • 6 fixed programs + 2 user presets + custom mode
  • Timer: 1–60 minutes or Infinity mode
  • Pulse function: off or 1–40 Hz
  • Single and dual setup with shared control
  • Touch display directly on the panel
  • True power switch: no standby mode
  • Shielded cables with ferrite filters

Manufacturer Lichtblock GmbH
Model LB-FORTE
Scope of delivery Forte red light panel, power cable, ferrite filter, power connection cable, data cable, 4 spacers, protective goggles, user manual

Technical data

Product Forte – Red light panel
Model LB-FORTE
Wavelengths 630 / 660 / 810 / 850 nm
LEDs 450 dual-chip LEDs (900 LED chips)
LED chip distribution 225 chips per wavelength
Designed LED lifespan 50,000 operating hours
Intensity control Red light and near-infrared light independently from 0–100%
Dimming technology Analog dimming via 0–10 V control signal
Flicker behavior Flicker-free – View measured values
Programs 6 fixed presets, 2 user presets, custom mode
Timer 1–60 minutes / Infinity mode
Pulse frequency 0–40 Hz
Operation Touch control panel
Linked operation Single or dual setup via master/follow
Rated electrical power 670 W
Operating voltage 100–240 V AC, 50/60 Hz
EMF measured values 30 cm: 31 nT / 0,6 V/m
50 cm: 10 nT / 0 V/m
100 cm: 0 nT / 0 V/m
Magnetic / electric alternating field
Measuring device: Gigahertz Solutions NFA 1000
Housing Aluminum alloy
Dimensions 45 × 91 × 6,5 cm (W/H/D)
Weight 19 kg
Protection rating IP20
Operating temperature −10 °C to 45 °C
Storage temperature 0 °C to 55 °C

Irradiance and Light Distribution

Irradiance was measured with our Hopoocolor OHSP-350IR spectrometer at 100% red light and near-infrared, with the pulse function deactivated. Measurements were taken at the center (Center), halfway to the edge (Midway), and at the edge (Edge) of the panel.

The results show uniform light distribution across the measured positions, as well as consistently high irradiance at greater distances.

Forte irradiance at distances of 30 to 90 cm Measurement positions Center, Midway and Edge on the Forte panel
Distance Center Midway Edge
30 cm58,658,454,1
45 cm57,454,649,9
60 cm56,351,645,6
90 cm49,042,537,8

All values in mW/cm². Measurement positions as shown in the graphic, sensor height approx. 50 cm.

Irradiance at greater distances

Distance Irradiance (Center)
120 cm44,6 mW/cm²
150 cm35,3 mW/cm²
200 cm25,3 mW/cm²

At greater distances, measurements were taken exclusively at the center (Center). The values are based on our own measurement series and may vary depending on the measuring device, measurement position, and measurement conditions.


Frequently asked questions about irradiance

Why do the irradiance values from different manufacturers sometimes differ significantly?

There is currently no universally applied industry standard for measuring the irradiance of red light panels. In particular, the measuring device used, the measurement distance, and the measurement position all affect the results.

Solarmeters can display significantly higher values than spectrometers. We consider a suitable spectrometer to be the more precise measurement method because it can capture irradiance with spectral resolution. That is why we use an OHSP-350IR spectrometer for our measurements and disclose the measurement conditions.

Some manufacturers already publish values from both measurement methods, while others provide Solarmeter values only. If you want to compare different red light panels, you should therefore also pay attention to the measurement method used and ask the manufacturer directly if anything is unclear.

Why don’t we provide measurement values at a distance of 15 cm?

In our own measurement series, we found that even minimal changes in measurement position or alignment at a distance of 15 cm can lead to significant deviations. One key factor is, among others, how the light from the individual LEDs falls onto the 10 mm entrance optics of our spectrometer.

Reliable and reproducible measurement is extremely difficult under these conditions. Since 15 cm is not particularly practical for real-world use of a red light panel anyway, we do not provide this value. From 30 cm onward, our measurements were significantly more stable and could also be reproduced reliably across several consecutive individual measurements.

How was the irradiance of the Forte measured?

For our measurement series, we use an OHSP-350IR spectrometer that, according to the manufacturer, is explicitly intended for measurements on red light devices as well. Its spectral range of 380–1050 nm covers all four wavelengths of the Forte panel.

We measured at precisely defined distances. Red light and near-infrared were each set to 100%, and the pulse function was deactivated. Measurements were taken at the center (Center), halfway to the edge (Midway), and at the edge (Edge) of the panel. At distances of 120, 150, and 200 cm, only the irradiance at the center was recorded.

The published values are guideline values rounded to one decimal place, based on our measurement series.

Does higher irradiance automatically mean better results?

No. Studies on photobiomodulation show that the effect depends on several factors, especially the wavelengths, the irradiance, and the duration of use. The so-called biphasic dose-response relationship is also well known: more light does not necessarily lead to a stronger biological effect.

Our Forte combines four wavelengths with broad, uniform illumination and individually adjustable intensity. This makes it possible to control different light doses precisely through the duration of use.


Flicker Performance (Flicker)

The Forte was measured with a professional Hauser ZadPad with VLP Light Flicker Probe at various brightness settings and with the pulse function disabled.

Red NIR Flicker Modulation Flicker Index SVM
1%1%0,4%0,7%0,000,00
21%26%0,3%0,6%0,000,00
73%48%0,3%0,5%0,000,00
92%98%0,3%0,6%0,000,00
100%100%0,3%0,6%0,000,00

Result: Forte is flicker-free across the entire tested dimming range. Flicker Index and SVM remain consistently at 0.00, while the measured modulation is only 0.5–0.7%.

Why is this possible? Forte uses analog dimming with a 0–10 V control signal. Unlike traditional PWM dimming, where the LEDs are rapidly switched on and off to regulate brightness, analog dimming controls the LED current. This keeps the light output nearly constant – even at very low brightness.

Do you have questions?

Our FAQ page may help. If not, feel free to send us an email at support@lichtblock.shop

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Reviews in Other Languages