Lichtblock® Forte dual setup with vertical stand
This bundle combines two Forte red light panels with the vertical Forte stand. This creates a continuous area of 45 × 182 cm for large-area application of red and near-infrared light.
Easy operation directly on the panel
Forte is operated via the touch display integrated on the side. Here you can select presets and make your own settings. The two panels can be connected to each other using the included data cable and controlled together in master/follow mode.
6 presets for different applications
Forte offers six fixed presets for different applications. Simply choose the desired preset and start the application with the settings already stored.
For energizing applications.
Red 100% / NIR 100%
10 min. / 40 Hz
For short applications before physical activity.
Red 100% / NIR 100%
5 min. / Pulse off
For applications after physical exertion.
Red 100% / NIR 100%
10 min. / Pulse off
For relaxing applications and rest periods.
Red 50% / NIR 50%
20 min. / 10 Hz
For evening applications.
Red 0% / NIR 100%
10 min. / Pulse off
For targeted applications on the face or skin.
Red 100% / NIR 100%
3 min. / Pulse off
Your own programs
In addition to the six fixed programs, Forte offers two user presets that you can configure and save freely. This lets you call up your preferred configuration again at any time.
For your own programs and in custom mode, you can choose the intensity of red light and near-infrared individually, set a duration between 1 and 60 minutes or select infinity mode, and activate a pulse frequency between 1 and 40 Hz if needed. The pulse function is also part of the fixed programs Relax & Meditation with 10 Hz and Energy with 40 Hz.
Red light and near-infrared with four wavelengths
Forte combines visible red light at 630 and 660 nm with near-infrared light at 810 and 850 nm. Both spectral ranges have been intensively studied in photobiomodulation research for many years. Red light and near-infrared can be adjusted independently of each other in their intensity or used together.
Each panel contains 450 dual-chip LEDs with a total of 900 LED chips. Each of the four wavelengths is allocated 225 chips.
Original graphic of the spectral measurement in combined operation of red light and near-infrared light.
Red light and near-infrared light in research
The application of red and near-infrared light is often grouped under the term photobiomodulation and has been studied scientifically for many years. Among other things, research examines how light of specific wavelengths is absorbed by cells and how it can influence biological processes there.
Mitochondria play an important role here, as they are responsible for energy production in our cells. In research, changes in cellular energy metabolism and various signaling processes are described, among other things. Photobiomodulation is now being studied in different areas, for example in connection with physical activity and recovery, as well as skin and general well-being.
How light works biologically does not depend on wavelength alone. Intensity, duration, distance, and the total amount of light absorbed also play a role.
Control two panels together
The two Forte panels can be connected to each other using the included data cable. You then select one panel as the master and the second as the follower. Both panels can then be controlled together via the touch display of the master panel.
Using the included power connection cable, the follower panel can be powered via the master panel. This allows both panels to be switched on and off together using the power switch on the master panel. The power switch of the follower panel remains switched on, but the panel receives no power when the master panel is switched off.
Vertical stand for the dual setup
The vertical Forte stand makes it possible to use two panels arranged one above the other. The two panels are connected together on the back using the included connecting pieces and mounted on the stand. Thanks to the casters, the setup can be positioned flexibly in the room. The height of the stand can be adjusted during assembly..
Dimensions of the vertical stand
All features at a glance
- 2 Forte red light panels with a continuous area of 45 × 182 cm
- 4 wavelengths: 630, 660, 810 and 850 nm
- 450 dual-chip LEDs per panel with 900 LED chips each
- Red light and near-infrared intensity adjustable independently
- 6 fixed programs + 2 user presets + custom mode
- Timer: 1–60 minutes or infinity mode
- Pulse function: off or 1–40 Hz
- Dual setup with shared control via Master/Follow
- Shared on/off switching via the master panel’s power switch
- Vertical stand with casters and adjustable height
- Touch display directly on the panel
- True power switch: no standby mode
- Shielded cables with ferrite filters
| Manufacturer | Lichtblock GmbH |
|---|---|
| Included models | 2 × LB-FORTE, 1 × LB-FORTE-VERTICAL-STAND |
| Scope of delivery | 2 Forte red light panels, 2 power cords, 2 ferrite filters, 2 power connection cables, 2 data cables, 8 spacers, 2 protective goggles, 2 user manuals, Vertical Forte stand, assembly instructions |
Technical data
| Product | Forte – red light panel |
|---|---|
| Model | LB-FORTE |
| Wavelengths | 630 / 660 / 810 / 850 nm |
| LEDs | 450 dual-chip LEDs (900 LED chips) per panel |
| LED chip distribution | 225 chips per wavelength and panel |
| Rated LED lifespan | 50,000 operating hours |
| Intensity control | Red light and near-infrared independently from 0–100% |
| Dimming technology | Analog dimming via 0–10 V control signal |
| Flicker behavior | Flicker-free – View measured values |
| Programs | 6 fixed presets, 2 user presets, custom mode |
| Timer | 1–60 minutes / Infinity mode |
| Pulse frequency | 0–40 Hz |
| Operation | Touch control panel |
| Linked operation | Dual setup via Master/Follow |
| Rated power | 670 W per panel (1,340 W total) |
| Operating voltage | 100–240 V AC, 50/60 Hz |
| EMF measured values |
30 cm: 31 nT / 0,6 V/m 50 cm: 10 nT / 0 V/m 100 cm: 0 nT / 0 V/m Magnetic / electric alternating field Measured values of a single panel; measuring device: Gigahertz Solutions NFA 1000 |
| Housing | Aluminum alloy |
| Dimensions | 45 × 91 × 6,5 cm (W/H/D) per panel |
| Dimensions in dual setup | 45 × 182 cm (without gaps) |
| Weight | 19 kg per panel (38 kg total, without stand) |
| Protection rating | IP20 |
| Operating temperature | −10 °C to 45 °C |
| Storage temperature | 0 °C to 55 °C |
Irradiance and light distribution
The irradiance was measured with our Hopoocolor OHSP-350IR spectrometer at 100% red light and near-infrared with the pulse function disabled. Measurements were taken at the center (Center), halfway to the edge (Midway), and at the edge (Edge) of the panel.
The results show even light distribution across the measured positions and consistently high irradiance even at greater distances.
| Distance | Center | Midway | Edge |
|---|---|---|---|
| 30 cm | 58,6 | 58,4 | 54,1 |
| 45 cm | 57,4 | 54,6 | 49,9 |
| 60 cm | 56,3 | 51,6 | 45,6 |
| 90 cm | 49,0 | 42,5 | 37.8 |
All values in mW/cm². Measurement positions according to the graphic, sensor height approx. 50 cm.
Irradiance at greater distances
| Distance | Irradiance (Center) |
|---|---|
| 120 cm | 44.6 mW/cm² |
| 150 cm | 35.3 mW/cm² |
| 200 cm | 25.3 mW/cm² |
At greater distances, measurements were taken exclusively at the center (Center). The values are based on our own series of measurements and may vary depending on the measuring device, measurement position, and measurement conditions.
Frequently asked questions about irradiance
Why do the irradiance values from different manufacturers sometimes differ significantly?
There is currently no uniformly applied industry standard for measuring the irradiance of red light panels. In particular, the measuring device used, the measurement distance, and the measurement position influence the results.
Solarmeters can show significantly higher values than spectrometers. We consider a suitable spectrometer to be the more precise measurement method, as it can capture irradiance with spectral resolution. That is why we use an OHSP-350IR spectrometer for our measurements and disclose the measurement conditions.
Some manufacturers already publish values from both measurement methods, while others only provide Solarmeter values. Anyone who wants to compare different red light panels should therefore also pay attention to the measurement technology used and, if anything is unclear, ask the manufacturer directly.
Why don’t we provide measurement values at a distance of 15 cm?
In our own measurement series, we found that even minimal changes in the measurement position or alignment at a distance of 15 cm can lead to significant deviations. One decisive factor is how the light from the individual LEDs hits the 10 mm entrance optics of our spectrometer.
Reliable and reproducible measurement is extremely difficult under these conditions. Since 15 cm is not very practical anyway for the use of a red light panel, we do not provide this value. From 30 cm onward, our measurements were much more stable and could also be reliably reproduced across multiple consecutive individual measurements.
How was the irradiance of the Forte measured?
For our measurement series, we use an OHSP-350IR spectrometer, which the manufacturer explicitly also specifies for measurements on red light devices. Its spectral range of 380–1050 nm covers all four wavelengths of the Forte panel.
We measured at precisely measured distances. Red light and near infrared were each set to 100%, and the pulse function was deactivated. Measurements were taken at the center (Center), halfway to the edge (Midway), and at the edge (Edge) of the panel. At distances of 120, 150, and 200 cm, only the irradiance at the center was recorded.
The published values are guide values rounded to one decimal place based on our series of measurements.
Does higher irradiance automatically mean better effectiveness?
No. Studies on photobiomodulation show that the effect depends on several factors, especially the wavelengths, the irradiance, and the duration of use. The so-called biphasic dose-response relationship is also well known: More light does not necessarily lead to a stronger biological effect.
Our Forte combines four wavelengths with broad, even illumination and individually adjustable intensity. This allows different light doses to be controlled precisely via the duration of use.
Flicker behavior (flicker)
The Forte was measured with a professional Hauser ZadPad with VLP Light Flicker Probe at various brightness settings and with the pulse function deactivated.
| Red | NIR | Flicker | Modulation | Flicker Index | SVM |
|---|---|---|---|---|---|
| 1% | 1% | 0.4% | 0.7% | 0.00 | 0.00 |
| 21% | 26% | 0.3% | 0.6% | 0.00 | 0.00 |
| 73% | 48% | 0.3% | 0.5% | 0.00 | 0.00 |
| 92% | 98% | 0.3% | 0.6% | 0.00 | 0.00 |
| 100% | 100% | 0.3% | 0.6% | 0.00 | 0.00 |
Result: Forte is flicker-free across the entire dimming range examined. Flicker Index and SVM remain consistently at 0.00, and the measured modulation is only 0.5–0.7%.
Why is this possible? Forte uses analog dimming with a 0–10 V control signal. Unlike classic PWM dimming, where the LEDs are switched on and off rapidly to regulate brightness, analog dimming regulates the LED current. This keeps the light output nearly constant – even at very low brightness.
Do you have questions?
Our FAQ page may help. If not, feel free to send us an email at support@lichtblock.shop
4.9 / 5 | 2847